A/C, Single Phase, Split Gas Furnace Single Stage, Multi Position Power "V" H4A6S/N92MSN/EVM4X
Air Conditioner Condenser
- 80% AFUE
- Flame roll-out sensors standard
- Category I venting
- Blocked vent switch
- Louvered door
- 24 VAC and 115 VAC humidifier terminal
- Electronic air cleaner terminal
- Select sizes approved for twinning, refer to accessory kit listing
- N80ESL - Low NOx units are designed for California installations and can be installed in air quality management districts with a 40ng/J NOx emissions limit
- Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193
- Adjustable heating blower OFF delay
- Factory set blower ON delay
- RPJ aluminized steel heat exchanger
- High temperature limit control designed to prevent overheating
- Direct ignition with Silicon Nitride igniter
- One piece prepainted steel cabinet
- In-shot burners
- 33 1/3” (847mm) high, for ease of installation
- Quarter turn knobs for easy door removal and secure attachment
- Factory shipped for natural gas, convertible to propane with accessory kit
- Four position - upflow/downflow/horizontal (left/right) installation
- Three position inducer elbow capability
- Through the casing flue pipe for counterflow applications
- Common venting with other Category I appliances
- Masonry chimney adapter available
- Self diagnostics
- Slide out blower assembly
Gas Furnace
- Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized to 1 inch water column with all present air inlets, air outlets, and condensate drain port(s) sealed
- Approved for Manufactured Housing/Mobile Home application with accessory (order separately)
- 18 Speed EC Constant Torque Motor (set up w/ app)
- RPJ aluminized steel primary heat exchanger
- Stainless Steel Secondary Heat Exchanger
- Direct ignition with Silicon Nitride ignitor
- Direct vent (2-pipe), single-pipe venting, or ventilated combustion air
- 35” (889mm) high, for ease of installation
- Simplified factory installed internal condensate drain system
- Four position - upflow/downflow/horizontal (left/right) installation
- At least twelve different venting configurations
- Through the casing flue pipe for counterflow or horizontal applications with accessory (order separately)
- Concentric vent available
- Self diagnostics with 3 digit codes
- Twinning Capable - w/ kit (select sizes)
Evaporator Coil
- Corrosion Resistant Aluminum
- Low Pressure Drop
- TXV metering device factory installed
- Compact design, shorter than A-coils
- Hemmed flanges for safer handling
- Cabinets meet or exceed 2% air leakage codes
- UV knockout
- No delta plate allows easy cleaning
- 30-40% Lighter than “A” Coils
- 80% Fewer Factory Braze Joints vs. “N” Coils
- V Design Reduces Cabinet Sweating
- Helium leak tested @ the factory